Emerson F145 1328 Thermostat User Manual

Home

href="
EMERSON BLUE 12”  
TOUCHSCREEN THERMOSTATS  
BLUE 12" TOUCHSCREEN - UNIVERSAL AND  
SINGLE STAGE MODELS - 12 SQ. IN. DISPLAY  
Offers the Ultimate in Comfort, Convenience, Performance  
and Visibility.  
FEATURES  
ꢀUniversalꢀmodelsꢀquicklyꢀconfigureꢀforꢀsingleꢀstage,ꢀmulti-stage,ꢀheatꢀpumpꢀandꢀꢀ  
heatꢀpumpꢀdualꢀfuelꢀsystemsꢀ-ꢀprogrammableꢀorꢀnon-programmable.  
Humidity controlꢀoffersꢀhumidification/dehumidification.  
Commercial offersꢀoccupiedꢀdamperꢀorꢀeconomizerꢀcontrol.  
Stagingꢀcontrolꢀforꢀnearlyꢀallꢀconventionalꢀandꢀheatꢀpumpꢀsystems.  
Single stageꢀmodelꢀcompatibleꢀwithꢀallꢀsingleꢀstageꢀsystemsꢀlowꢀvoltage,ꢀ750ꢀmV,ꢀꢀ  
3-wireꢀzoneꢀsystemsꢀandꢀ2H/1Cꢀheatꢀpumpꢀsystems.  
1
F95-1291  
ꢀHeatꢀPumpꢀdualꢀfuelꢀoptionꢀeliminatesꢀtheꢀneedꢀforꢀaꢀfossilꢀfuelꢀkit.  
ꢀAutomaticꢀchangeoverꢀoption.  
ꢀProgramꢀfanꢀoptions.ꢀ  
ꢀKeypadꢀlockoutꢀandꢀsetpointꢀtemperatureꢀlimitꢀoptions.  
ꢀIndoorꢀremoteꢀsensorꢀforꢀaveragingꢀoption.  
ꢀOutdoorꢀremoteꢀsensorꢀoption.ꢀAddꢀtoꢀUniversalꢀmodelsꢀforꢀoutdoorꢀtempꢀreadingꢀor,ꢀꢀ  
onꢀselectꢀmodels,ꢀdualꢀfuelꢀbalanceꢀpointꢀandꢀoutdoorꢀthermostatꢀfunctions.  
ꢀDualꢀpowerꢀ-ꢀhardwireꢀand/orꢀbatteryꢀ(1F95-1277ꢀandꢀ1F97-1277)ꢀorꢀTripowerꢀ-ꢀꢀ  
hardwireꢀand/orꢀbatteryꢀwithꢀsystemꢀassistꢀ(1F95-1291ꢀandꢀ1F95-1280).  
SPECIFICATIONS  
ElectricalꢀRating:  
Hardwire . . . . . . . . . . . . . . . . . . . . . . . .ꢀ 20-30ꢀVAC,ꢀNECꢀClassꢀIIꢀ50/60Hz  
BatteryꢀPower. . . . . . . . . . . . . . . . . . . .ꢀ mVꢀtoꢀ30ꢀVAC,ꢀNECꢀClassꢀII,ꢀ50/60ꢀHzꢀorꢀDC  
TerminalꢀLoad. . . . . . . . . . . . . . . . . . . .ꢀ 1.5ꢀAꢀperꢀterminal,  
1
F95-1277  
ꢀ 2.5ꢀAꢀmaximumꢀallꢀterminalsꢀcombined  
SetpointꢀRange. . . . . . . . . . . . . . . . . . .ꢀ 45ꢀtoꢀ99°Fꢀ(7ꢀtoꢀ37°C)  
RatedꢀDifferentials:. . . . . . . . . . . . . . . .ꢀ Fastꢀ  
Heatꢀ(SingleꢀStage/Multi-Stage). . . . . .ꢀ 0.4°Fꢀ  
Coolꢀ(SingleꢀStage/Multi-Stage) . . . . . .ꢀ 0.9°Fꢀ  
HeatꢀPump . . . . . . . . . . . . . . . . . . . . . .ꢀ 0.9°Fꢀ  
Emer.ꢀHeat . . . . . . . . . . . . . . . . . . . . . . 0.6°Fꢀ  
Med.ꢀ  
0.6°Fꢀ  
1.2°Fꢀ  
1.2°Fꢀ  
Slow  
1.7°F  
1.7°F  
1.7°F  
1.7°F  
OperatingꢀAmbient . . . . . . . . . . . . . . . . 32ꢀtoꢀ+105°Fꢀ(0ꢀtoꢀ+41°C)  
OperatingꢀHumidity. . . . . . . . . . . . . . . .ꢀ 90%ꢀnon-condensingꢀmax.  
ShippingꢀTemperatureꢀRange. . . . . . . .ꢀ -4ꢀtoꢀ+150°Fꢀ(-20ꢀtoꢀ65°C)  
F145-1328  
Indoor Remote Sensor  
9
13  
13  
Dimension. . . . . . . . . . . . . . . . . . . . . . . 4 /16ꢀHꢀxꢀ5 /16Wꢀxꢀ1 /16D  
PARTS AND ACCESSORIES Seeꢀendꢀofꢀthisꢀsectionꢀforꢀadditionalꢀpartsꢀandꢀaccessories  
ꢀF145-1328ꢀ—ꢀIndoorꢀremoteꢀsensor  
ꢀF145-1378ꢀ—ꢀOutdoorꢀremoteꢀsensor  
1
3
8
ꢀF61-2600ꢀ—ꢀWallplateꢀ8 /  
8
Wꢀxꢀ5 /  
H  
1
ꢀF61-2634ꢀ—ꢀWallplateꢀ6 /  
2
Wꢀxꢀ5Hꢀ(orꢀorderꢀF61-2648ꢀ–ꢀ6ꢀpackꢀofꢀF61-2634)  
ꢀF29-0198ꢀ—ꢀLockingꢀThermostatꢀGuardꢀ-ꢀClearꢀPlastic  
ꢀF29-0220ꢀ—ꢀLockingꢀThermostatꢀGuardꢀ-ꢀMetal,ꢀSolidꢀBase  
ꢀAdditionalꢀThermostatꢀGuardsꢀ—ꢀseeꢀpagesꢀ24-25ꢀforꢀquickꢀselectionꢀoptions  
F145-1378  
Outdoor Remote Sensor  
8-a  
www.white-rodgers.com  
href="
1F95-1277 .....................  
                                                                                                                              
EMERSON BLUE 12”  
TOUCHSCREEN THERMOSTATS  
UNIVERSAL STAGING/HEAT PUMP THERMOSTATS – EMERSON BLUE 12 THERMOSTATS  
Comfort and  
Convenience  
Features  
Single Multi- Heat  
Programs  
Model  
Applications  
Selectable Performance Features  
Stage Stage Pump  
Terminals  
Periods  
Per Day  
Options  
Stages Heat/Cool Program  
by System Options  
Model  
Number  
1
1
1
/1  
2/2  
2/2  
4/2 7,ꢀ5+1+1,ꢀ 4,ꢀ2,ꢀØ 1F95-1291  
3
3
3
3
3
3
3
3
3
H,ꢀD B,ꢀH,ꢀ 3  
3
3
3
3
3
3
L,ꢀO T,ꢀP  
3
3
3
1+1 1t 12.0 3***  
3
3
3
P
RC,ꢀRH,ꢀC,ꢀG,ꢀY,ꢀY2,ꢀ  
W/E,ꢀW2,ꢀO/B,ꢀL,ꢀ+,ꢀ  
S,ꢀ-,ꢀ6,ꢀDHM,ꢀHM  
Ø
Humidity  
PA  
Control  
/1  
/1  
4/2 7,ꢀ5+1+1,ꢀ 2,ꢀØ  
1F95-1280  
3
B,ꢀH,ꢀ 3  
PA  
L,ꢀO T,ꢀP  
1+1 1t 12.0 3***  
1+1 1t 12.0 3***  
P
P
RC,ꢀRH,ꢀC,ꢀG,ꢀY,ꢀY2,ꢀ  
W/E,ꢀW2,ꢀO/B,ꢀL,ꢀ+,ꢀ  
S,ꢀ-,ꢀ6,ꢀA1  
Ø
Commercial  
2/2 3/2◙ 7,ꢀ5+1+1,ꢀ 4,ꢀ2,ꢀØ 1F95-1277  
Universal  
B,ꢀH  
3
O
T,ꢀP  
RC,ꢀRH,ꢀC,ꢀW/E,ꢀW2,ꢀ  
Y,ꢀY2,ꢀG,ꢀO,ꢀB,ꢀ6,ꢀL,ꢀ  
Ø
+
,ꢀS,ꢀ-  
SINGLE STAGE THERMOSTAT – EMERSON BLUE 12 THERMOSTATS  
Comfort and  
Convenience  
Features  
Single Multi- Heat  
Programs  
Model  
Applications  
Selectable Performance Features  
Stage Stage Pump  
Terminals  
Periods  
Per Day  
Options  
Stages Heat/Cool Program  
by System Options  
Model  
Number  
1/1  
2/1 7,ꢀ5+1+1,ꢀ 4,ꢀ2,ꢀØ 1F97-1277  
3
3
3
B,ꢀH  
3
3
3
3  T,ꢀP  
3
1+1 1t 12.0 3***  
3
P
RC,ꢀRH,ꢀC,ꢀW/E,ꢀY,ꢀ  
G,ꢀO,ꢀB,ꢀL,ꢀ6,ꢀ+,ꢀS,ꢀ-  
Ø
*ꢀ Hꢀ=ꢀHardwiredꢀ(RequiresꢀCommon)ꢀ  
IfꢀF145-1378ꢀoutdoorꢀremoteꢀsensorꢀisꢀnotꢀused,ꢀinstallꢀmanufacturersꢀꢀ ꢀ  
fossilꢀfuelꢀkitꢀforꢀDualꢀFuelꢀapplications  
B,ꢀHꢀ=ꢀBatteryꢀPoweredꢀorꢀHardwiredꢀ  
Bꢀ=ꢀBatteryꢀPoweredꢀ  
PAꢀ=ꢀPowerꢀSavingꢀBatteryꢀAssistꢀ  
***ꢀOptionalꢀContinuousꢀDisplayꢀLightꢀw/ꢀHardwireꢀconnection  
tꢀ Onlyꢀoneꢀ(1)ꢀremoteꢀsensorꢀmayꢀbeꢀusedꢀ–ꢀeitherꢀIndoorꢀorꢀOutdoorꢀ  
◙ꢀ 4/2ꢀonꢀDualꢀFuelꢀusingꢀOutdoorꢀRemoteꢀSensor  
TECHNICAL HELP  
1
1
F97-1277 .....................  
F95-1280ꢀ/ꢀ1F95-1291. WiringꢀDiagrams/Configuration...............Seeꢀpagesꢀ128-131  
WiringꢀDiagrams/Configuration...............Seeꢀpagesꢀ132-133  
?
PAGES  
126-133  
www.white-rodgers.com  
9-a  

Aprilaire 8600 Thermostat User Manual

White Rodgers 1F92W 71 Thermostat User Manual

Honeywell 69 1815EFS 04 Thermostat User Manual

Honeywell T921A Thermostat User Manual

Honeywell Q539G Thermostat User Manual

White Rodgers 37 7248A Thermostat User Manual

White Rodgers 1F95 80 Thermostat User Manual

Honeywell T8700B Thermostat User Manual

Honeywell 63 4526 01 Thermostat User Manual

Bryant T6 PRH A Thermostat User Manual